Posts

Showing posts from October, 2026

FTAS 4.1: AI Factory Automation, Expanded FMCLI Coverage, and Large-Scale Validation

Image
We’re excited to announce FTAS 4.1. This release adds 142 new test cases and brings the framework to 1,072 test cases in total. Its headline feature is automated validation for AI Factory fabrics. Spotlight: AI Factory (N-S) automation FTAS 4.1 adds an ordered 39-case AI Factory test plan that checks the full ONES-driven fabric lifecycle: Design and planning: fabric types, scalable units, tenancy modes and network planes. Deployment and onboarding: fabric deployment and tenant orchestration. Control-plane parity: ONES API inventory compared with the switch CLI. Data-plane proof: Ixia traffic across the deployed fabric. By the numbers Category Total SONiC Framework 599 FMCLI 188 Telemetry 285 Total FTAS test cases 1072 What else is new FTAS with FMCLI: 54 new test cases bring FMCLI coverage to 188. BGP convergence at IPv6 scale: 18 tests at 32k, 64k and 128k routes. L3VNI multi-tenancy: 12 tests cover 3 VRFs with 128 VLANs. BFD session scale: 4 tests with 64 and 128 sessions. A...

How SONiC 202611 Shows You Exactly Why Packets Are Dropped

Image
Packet loss in an AI factory is hard to troubleshoot. Distributed compute depends on the network across large clusters, and when packets go missing, engineers need to know three things: which packets, where they were dropped, and why. Interface counters only answer one question: did drops happen? SONiC 202611 changes that with per-packet drop notifications carried in sFlow. Why counters fall short Look at what a counter gives you on leaf-2: Ethernet12 rx_discards +4,112 over 5 min Now look at what a drop notification gives you for the same event: 4,112 records showing traffic from 10.1.4.7 to 10.1.9.2 on UDP 4791, ingress Ethernet12, group acl_drops , trap ingress_flow_action_drop . In plain terms, a RoCEv2 flow that a new ACL just blocked. The counter is a number. The notification is an answer. The problem with vendor-only tools Vendor drop telemetry has existed for years. NVIDIA’s What Just Happened is the best-known example. But it works on one ASIC family and one export path. SONi...

What Does It Take to Run a Multi-Tenant GB200 or GB300 GPU Service Reliably?

Image
Introduction Once an operator decides to offer rack-scale GPUs as a shared service, the question becomes, "How do we ensure tenant isolation?" rather than, "Can we offer tenant isolation?" NVL72 systems interconnect 72 Blackwell GPUs using NVLink, and racks are interconnected using an InfiniBand scale-out fabric. Isolation is needed at both the interconnect and fabric level, and both have to agree. Here we focus on the interconnect side of this problem. Why Isn't a VLAN Enough Here? As NVLink doesn’t follow traditional Ethernet behaviors, methods used to isolate Ethernet tenants do not work here. Isolation needs to occur in the fabric. Full NVLink bandwidth is preserved in the hardware-level GPU partition. There is no connectivity to other partitions. How Do Single-Rack and Multi-Rack Tenants Differ? In a single rack, a tenant requires NVLink partitioning. A tenant spanning multiple racks requires NVLink partitions and a private InfiniBand partition spanning the...

How Do You Operate Host-Based Networking Across Hundreds of DPUs?

Image
  Introduction Moving networking functions into each host addresses a scaling issue but creates an operations issue. Instead of a single leaf carrying the state for a rack, you have a router in every server. These routers need consistent BGP, EVPN, and tenant configuration and need to be in sync with the leaf switches they peer with. This document will address the operations side of the problem. We will demonstrate how the design and implementation of a fabric leads to a running HBN fabric and discuss where automation and validation prevent the problems that would occur with manual work. How Is HBN Turned On in ONES? Configuration is in the Network Setup section under N-S Network Settings. Enabling DPU HBN requires just one switch, but changes how ONES models the entire fabric. VTEP termination is now done at the DPU, not the leaf. ONES programs the DPUs directly, requiring DPU IPs and credentials instead of host entries. Five coupled settings define the N-S network model. The Oper...